52.28.8 AQM Measurement
Configuration property:
Algorithm: One of PESQ, POLQA NB, and POLQA SWB. Please note that POLQA can be measured only in the ACU TerraTec configuration (Measurement Type = "M2M DL + UL"). |
Measurement Type: M2F DL + UL: Mobile-to-fixed audio quality measurement using CallGenerator. M2M DL: Mobile-to-mobile audio quality measurement using Mobile Receiving Unit (MRU). M2M DL + UL: Mobile-to-mobile audio quality measurement using Audio Capturing Unit (ACU TerraTec). |
AQM Duration: The length of time for which to collect audio quality measurements (" |
Audio Channel (only used for M2M DL + UL, otherwise has the value "None"): Channel1: Choose this channel for the phone connected to LINE IN 1/LINE 0;OUT 0;1 on the ACU (TerraTec). Channel2: Channel for phone connected to LINE 0;IN 0;2/LINE 0;OUT 0;2. Channel3: Channel for phone connected to LINE 0;IN 0;3/LINE 0;OUT 0;3. Channel4: Channel for phone connected to LINE 0;IN 0;4/LINE 0;OUT 0;4. |
Recording Threshold (only used for M2M DL + UL): All audio files (*.pcm) with an AQM value worse than this threshold value will be stored under |