4 User-configurable Parameters

4 User-configurable Parameters
User-configurable parameters related to Diagnostic_Swapped_Feeders metric group output are found under Configuration | User Defined Parameter with ‘Diagnostic_Swapped_Feeders’ threshold set selected.
 
Technology
Compact Name
Default Value
Unit
Description
Scanner
AngleVersusPlannedAzimuthThreshold
90
degrees
Deviation from planned azimuth to trigger 'Covers wrong direction' scanner event
UE
AngleVersusPlannedAzimuthThreshold
90
degrees
Deviation from planned azimuth to trigger 'Swapped feeder indication' UE event
UE
DistanceToOtherSiteThreshold
1.5
km
Distance to other cell threshold used as 'Swapped feeder indication' UE event criterion for 'Connection dropped due to poor coverage, serving cell covers wrong direction or far away' event trigger
UE
DistanceToSiteThreshold
0.5
km
Distance to serving cell threshold used as 'Swapped feeder indication' UE event criterion for 'UE transmits at high Tx power close to cell site' event trigger
UE
DistanceToSiteThresholdNoService
1
km
Distance to last known serving cell threshold used as 'Swapped feeder indication' UE event criterion for 'Connection dropped in no service area close to a cell site' event trigger
UE
DownlinkCoverageThreshold
-105
dBm
Serving cell coverage threshold used as 'Swapped feeder indication' UE event criterion for 'Connection dropped due to poor coverage, serving cell covers wrong direction or far away' event trigger
UE
DownlinkCoverageThresholdForUETxPowerCheck
-100
dBm
Serving cell coverage threshold used as 'Swapped feeder indication' UE event criterion for 'UE transmits at low Tx power in poor coverage area' event trigger
UE
UETransmitPowerHighThreshold
21
dBm
UE Tx power threshold used as 'Swapped feeder indication' UE event criterion for 'UE transmits at high Tx power close to cell site' event trigger
UE
UETransmitPowerIncreaseThreshold
3
dBm
UE Tx power increase threshold used as 'Swapped feeder indication' UE event criterion for 'UE transmit power increased during failed handover attempt' event trigger
UE
UETransmitPowerLowThreshold
-20
dBm
UE Tx power threshold used as 'Swapped feeder indication' UE event criterion for 'UE transmits at low Tx power in poor coverage area' event trigger