4 User-configurable Parameters

4 User-configurable Parameters
User-configurable parameters related to NR_Pilot_Analysis metric group output are found under Configuration | User Defined Parameter | Default.
 
Technology
Compact Name
Default Value
Unit
Description
NR
NR_Pilot_Analysis: Hidden_Strong_Pilots_Alert_Threshold
6 dB
dB
Top1 hidden scanner pilot vs. Top1 serving cell pilot RSRP threshold
NR
NR_Pilot_Analysis: Min_Top1_over_Others
-3 dB
dB
Top1 scanner pilot vs. others combined RSRP threshold
NR
NR_Pilot_Analysis: Min_Top1_Serving_over_Top1_Non_Serving
-6 dB
dB
Top1 serving vs. Top1 non-serving scanner pilot RSRP threshold
NR
NR_Pilot_Analysis: Number_of_Poluters_Alert_Threshold
2
 
Minimum number of polluting pilots to generate Pilot Pollution Alert
NR
NR_Pilot_Analysis: Quality_Matrix_Poor_RSRP
-125 dBm
dBm
Poor RSRP threshold used in RSRQ_RSRP_Quality_Matrix
NR
NR_Pilot_Analysis: Quality_Matrix_Poor_RSRQ
-20 dB
dB
Poor RSRQ threshold used in RSRQ_RSRP_Quality_Matrix
NR
NR_Pilot_Analysis: RSRP_Threshold_Absolute
-130 dBm
dBm
Minimum polluter RSRP threshold
NR
NR_Pilot_Analysis: RSRP_Threshold_Relative
3 dB
dB
Polluter relative RSRP threshold